| Frequently
Asked Questions |
| |
What
chemicals are used to produce Envirolyte solutions? |
| They
are produced using a 0.5 to 1% solution of water and salt (NaCl
or KCl) plus electricity. |
| |
|
| What
does an Envirolyte generators do? |
| The
generator produces a 100% biodegradable, non-toxic liquid that can
replace harsher chemical formulations. |
| |
| What
liquids the generators produce? |
| The
generators produce three basic liquids: Acidic Anolyte, Neutral
Anolyte and Catholyte. |
| |
| What
will the liquids do? |
| The
Anolytes are guaranteed to remove and destroy all fungi, spores,
bio film, bacteria and viruses in milliseconds. The Catholyte is
a mild cleaning agent. |
| |
| What
is Acidic Anolyte? |
Acidic
Anolyte is an acid equivalent. It holds a pH value around 2-3
and can replace chemical agents where an acid agent is used. It
is guaranteed to yield better results and be more cost efficient. |
| |
What
is Catholyte? |
Catholyte
is a caustic soda equivalent. It holds a pH around 11-13 and can
replace chemical agents where caustic soda is used more efficiently
and at a far less cost then any chemical formulation. With Catholyte
processes like CIP can be accomplished using cold water yield
the same results as using caustic soda in warm water. |
| |
| What
is Neutral Anolyte? |
| Neutral
Anolyte is a mix of Acidic Anolyte and Catholyte. It holds a pH
of around 7.5-8.5 and can replace chemical formulations used for
rinsing and other tasks where acidity might be a liability. |
| |
What
are the active agents in the liquids? |
The
Anolytes consists of 99.6% water, 0.26% salt and 0.05% hypochlorous
acid, hypochlorite ion, hydrochloric acid with a touch of chlorine.
The generators contain one (or more) special electrolyte cells
that charge the water with an electrical charge. The concentrate
of liquid holds around 800 - 1,200 mV of charge (ORP), depending
on whether it is acidic or neutral anolyte. |
| |
What
is so special about this electrolyte cell compared to other similar
products? |
The
membranes in the cells are coated with a special alloy that enables
the cells to endure extremely high voltage throughput. Other electrolyte
cells on the market will only manage a voltage of around 8 volts,
and their lifetime is around 6-8 months. In the Envirolyte cells
the voltage is 4 times as high and life time is longer. |
| |
What
is the life expectancy of the Envirolyte Cells? |
Our
product line ships with a 1year factory warranty, although the
cells are expected to have a lifetime of 2 to 5 years, after which
only the cells need be replaced. |
| |
How
much liquid can the units produce? |
It
depends of the unit. We have units that produce from 400 to 20,000
liters a day. The solutions are in concentrated hence these could
be added or diluted in small ratio. |
| |
|
What
does the unit cost and what are the running costs? |
There
are no off-the-shelf prices. All of the units are customized for
their intended use. Prices are estimated to range from €7,000
to over €400,000, depending on the type of application.
Once the unit is installed, then the only running costs are ordinary
water, edible salt and electricity! |
| |
I
don’t see any reference to my industry on your website.
Does this mean that it can’t be used? |
No!
Envirolyte has deployed products in an endless range of industries
for sometime now. If you don’t see any referrals or white
papers concerning your industry on our site, please contact us
for more information. |
| |
Can
our company buy the solutions from Envirolyte? |
No!
We do not sell the solutions. We sell the generators that produce
the activated solutions. |
|
How
much do I need to dose in my application? |
Not
much, but it depends on the application. Envirolyte, however,
considers 5% dosing of the liquid in concentrate form to be a
high dosage. In drinking water normally 1:2000 (depending on the
contamination) is more then enough to remove all bacteria and
bio-film. |
Envirolyte
is a registered trademark with all rights reserved. System and
generators are patented worldwide.
All use of material without express permission from the company
will be prosecuted to the full extent of the law. |
| |
| |
Features
of Envirolyte and ECO Units |
| |
Envirolyte
(EL, EL-2, ELA) and Envirolyte ECO are registered trademarks for
Envirolyte products. The applications for this technology are
infinite and include any process requiring sterilization, disinfection
or water purification.
The environmental and ecological benefits in terms of reduction
in usage of chemicals are one of the prime factors for the use
of Envirolyte (EL, EL-2, ELA and ECO units. These systems can
be beneficial in any industry where wastewater and water processing
problems occur.
The Envirolyte units have been developed to automatically produce
activated solutions of different types and strength. They can
act as stand alone units or used in a continuous process in a
more complex system. Customized units are available.
|
A
self-cleaning cycle has been programmed into all machines to ensure
easy maintenance, maximum productivity and a long lifetime without
maintenance.
The unique design of the central cell ensures that the electrolyte
used to produce activated solutions has maximum contact with the
electrodes and therefore guarantees the most effective use of
energy and minimum waste of raw materials.
There is minimal hydraulic resistance against liquids flowing
through the cell chambers, which guarantees that optimum flow
rates are achieved.
The electrodes are specifically designed to endure high electrochemical
loading as are the membranes, which separate the solutions.
The control system is simple and easy to operate. It can be altered
to suit specific applications and conditions.
Stabilization of working current is introduced to ensure a stable
quality of the generated solutions.
Brine feed ventures and pinch valves are incorporated to ensure
accurate dosage under all conditions at any time.
The enclosure is made of non-corrosive materials. Tubes and connectors
are of EPDM/PVDF plastics and are highly resistant to aggressive
solutions.
All input and output connectors are located either at the rear
or at one side of the unit to enable easy installation.
A simple on/off switch with power indicator starts and stops the
unit manually.
Level-switches enable the unit to start and stop automatically.
All units are easy and safe to use.
Efficient: 1-5 minutes sterilization contact time.
Self cleaning, cost effective, fully automated, fixed strength
solutions.
Simple installation and maintenance.
Environmentally and ecologically friendly.
No moveable or replaceable parts.
|
The
Envirolyte units are built in different sizes to address different
applications. The units can be used where only small volumes of
disinfectants are required for domestic treatment or for large-scale
projects where disinfection, sterilization or water purification
are required. Changing the electrical input into the Envirolyte
units can also vary the strength of the solutions. |
|
Material
Safety Data Sheet 1 |
|
Envirolyte
ANK-Neutral Anolyte (91/155/EWG) |
|
|
Section
1: Product and Company Identification
Scientific Name: ANK-Neutral Anolyte
Trade Name: Aquasol - N
Manufacturer:
Envirolyte Industries International Ltd.
Narva str.1-330, 10111 Tallinn, Estonia
Indian Partner: Envirolyte AQUASOLUTIONS India
P.Ltd
|
Section
2: Composition and Information on the Ingredients
ANK-Neutral Anolyte contains active chlorine compounds such as
HCLO and CLO- (C.ac in mg/l) in the range of 0,001-0, 09%. The
average/standard amount of active chlorine is ~0, 05%. The solution
contains no compounds as per the regulations for toxic compounds
(67/548/EWG).
|
Section
3: Hazards Identification
The solution is classified as non dangerous accordingly
(88/279/EWG)
Main Hazards:
ANK-Neutral Anolyte in its strongest form (C.ac >600mg/l) may
cause irritation to the eyes, sensitive skin and throat. Where
the solution is stored in bottles one should try to smell or inhale
the evaporations.
Health effects Eyes:
ANK- Neutral Anolyte in its strongest form may cause irritation
to the eyes.
Health effects Skin:
ANK - Neutral Anolyte in its strongest form may cause slight irritation
to sensitive skin or open wounds.
Health effects Ingestion:
Swallowing of the solution in its strongest form may cause irritation
to the throat and digestive tract.
Health effects Inhalation:
During generation of ANK-Neutral Anolyte, particularly its strong
form, unless there is adequate ventilation there may be a build
up of fumes which may cause dizziness and nausea.
|
Section
4: First aid Measures
Eye contact:
Where irritation occurs flush with cool fresh water
Skin Contact:
Where irritation occurs wash the skin wash with soap and warm
water
Ingestion:
Drink cool fresh water to flush through and dilute
Inhalation:
Remove at once to fresh air if dizziness and nausea persist seek
medical attention
Section 5: Fire Fighting Measures.
|
Section
5: Fire Fighting Measures
There are no special requirements for ANK-Neutral Anolyte .It
is not flammable.
|
Section
6: Accidental Release Measures
Personal precautions:
None.
Environmental precautions:
The solution is biodegradable and has a limited activation period
so there are no potential risks to the environment.
Spillage:
Wipe up with disposable towels there are no special disposal instructions.
|
Section
7: Handling and Storage
Handling:
In the area where the solution is being produced there must be
good ventilation. Preferably local exhaust ventilation. For those
with very sensitive skin it may be advisable to wear gloves.
Storage:
Store in a cool dry ventilated area in sealed plastic containers
and ensure the solution is correctly labeled.
|
Section
8: Personal Protection and Exposure Control
Engineering control procedures:
Where the solution is being generated on site some engineering
solutions should be implemented to prevent the build up of fumes
particularly where productions facility has inadequate ventilation.
Mechanical fume extraction may be advised in this situation.
Documented process, safety controls and personnel protection where
necessary, gloves, mask etc.
Respiratory Protection:
Where there is a high risk to fumes build up due to inadequate
ventilation in a processing area a respirator should be worn.
Hand protection:
Where service personnel have sensitive skin the strongest solution
may cause irritation and therefore protective gloves should be
worn.
Eye and facial protection:
There are no requirements.
Body protection:
Normal industrial work wears to avoid exposed skin when handling
neat strong solution.
|
Section
9: Chemical and Physical Properties
Physical state: Liquid
Color and Appearance: Clear, transparent liquid
(like water)
Odour: Chlorine odor depending on strength of
the solution
Solubility in water: Completely soluble
PH-values: 7, 5 - 8, 5
Melting-point: 0oC.
Boiling-point: 100oC.
Fire-focus: N/A
Flammability: None
Explosive: N/A
Density: app. 1,000 kg.m3
Steam-pressure: app. 2,330 Pa
|
Section
10: Stability and Reactivity
Stability:
Stable under all normal storage conditions.
Materials to avoid:
The solution does not react with other materials
Hazardous decomposition products:
None
|
Section
11: Toxicological Information
Acute toxicity:
Not toxic
Irritant-Eyes:
Data for related material suggests this could produce conjunctivitis
irritation
Irritant-Skin:
Data for related material suggests this may cause skin irritation
Reproductive and developmental:
None known
Skin contact:
The possibility of allergic sensitization should be considered
Chronic toxicity/Carcinogens:
None
Human Data:
Inhalation may cause respiratory irritation
|
Section
12: Environmental Information
Eco toxicity:
Destroys bacteria, viruses, spores and algae
Degradability and Persistence:
Fully Biodegradable
Bio-accumulation:
None
Mobility:
None
|
Section
13: Disposal Procedures
There are no special disposal procedures.
|
Section
14: Transport procedures
Not classified as hazardous for transport
|
Section
15: Regulatory Information
Not listed
|
|
Section
16: Other Information
The information in this document meets the European requirements
for safety and health measurements. (91/155/EWG)
The
information contained in this document is based on data considered
to be accurate at the time of publication and is given free of
charge. It is representative of typical product but batches may
exhibit minor variations.
NO
warranty is expressed or implied concerning the
accuracy of this data.
In
case of doubt or for clarification Envirolyte Partner Company
should be consulted to determine Safety and Suitability for the
process and conditions of use.
This
information is intended for use in the EC-countries only as different
limits may be set in other countries. Please check your Local
and National Authorities or Supplier. (91/155/EWG)
©
2005, Envirolyte Industries International Ltd. Tallinn, Estonia
Envirolyte
AQUASOLUTIONS India P.Ltd. Salem-India
|
Material
Safety Data Sheet 2 |
Envirolyte
Acidic-Anolyte (91/155/EWG) |
|
|
Section
1: Product and Company Identification
Scientic Name: Acidic
Anolyte
Trade name: Aquasol - C
Manufacturer/Supplier:
Envirolyte Industries International Ltd.
Narva str.1-330, 10111 Tallinn, Estonia
Indian Partner: Envirolyte AQUASOLUTIONS India
P.Ltd
|
Section
2: Composition and Information on the Ingredients
Acidic Anolyte may contain active chlorine compounds such as CL2
and HCLO (C.ac in mg/l) in the range of 0,001- 0.09%. The average/standard
amount of active chlorine is ~ 0, 05%. The solution contains no
compounds as per the regulations for toxic compounds (67/548/EWG)
|
Section
3: Hazards identification
The solution is classified as non dangerous accordingly (88/279/EWG)
Main Hazards:
Acidic Anolyte in its strongest form (C.ac >500mg/l) may cause
irritation to the eyes skin and throat. Where the solution is
stored in bottles under no circumstances should anyone try to
smell or inhale the evaporations.
Health effects Eyes:
Acidic Anolyte in its strongest form may cause irritation to the
eyes.
Health effects Skin:
Acidic Anolyte in its strongest form may cause irritation to the
skin or open wounds.
Health effects Ingestion:
Swallowing of the solution in its strongest form may cause irritation
to the throat and digestive tract.
Health effects Inhalation:
During the generation of the solution particularly its strong
form, unless there is adequate ventilation, there may be a build
up of fumes which may cause dizziness and nausea.
|
Section
4: First aid Measures
Eye contact:
Where irritation occurs flush with cool fresh water
Skin Contact:
Where irritation occurs wash the skin wash with soap and warm
water
Ingestion:
Drink cool fresh water to flush through and dilute
Inhalation:
Remove at once to fresh air if dizziness and nausea persist seek
medical attention.
|
Section
5: Fire Fighting Measures
There are no special requirements for this solution. It is not
flammable.
|
Section
6: Accidental Release Measures
Personal precautions:
None
Environmental precautions:
These solutions are biodegradable and have a limited activation
period so there are no potential risks to the environment
Spillage:
Wipe up with disposable towels. There are no special disposal
instructions.
|
Section
7: Handling and Storage
Handling:
In the area where the solution is being produced there must be
good ventilation. Preferably local exhaust ventilation. For those
with very sensitive skin it may be advisable to wear gloves.
Storage:
Store in a cool dry ventilated area in sealed plastic containers
and ensure the solution is correctly labeled. Shelf life is up
to 12 months.
|
Section
8: Personal Protection and Exposure Control
Engineering control procedures:
Where Acidic Anolyte is generated on site some engineering solutions
should be implemented to prevent the build up of fumes particularly
if the production facility has inadequate ventilation. Mechanical
fume extraction may be necessary in this situation.
Documented process, safety controls and personnel protection where
necessary, gloves, mask etc.
Respiratory Protection:
Where there is a high risk to fumes build up due to inadequate
ventilation in a processing area a respirator should be worn.
Hand protection:
Where operatives have sensitive skin the strongest solutions may
cause irritation and therefore protective gloves should be worn.
Eye and facial protection:
There are no requirements
Body protection:
Normal industrial work wear avoid exposed skin where handling
neat strong solution.
|
Section
9: Chemical and Physical Properties
Physical state: Liquid
Color and Appearance: Clear liquid (like water)
Odour: Strong Chlorine odor
Solubility in water: Completely soluble
PH-values: 2, 0 - 3, 5
Melting-point: 0oC.
Boiling-point: 100oC.
Fire-focus: N/A
Flammability: None
Explosive: N/A
Density: app. 1,000 kg.m3
Steam-pressure: app. 2,330 Pa
|
Section
10: Stability and Reactivity
Stability:
Stable under all normal storage conditions
Materials to avoid:
Very corrosive on metals
Hazardous decomposition products:
None
|
Section
11: Toxicological Information
Acute toxicity:
Not toxic
Irritant-Eyes:
Data for related material suggests this could produce conjunctivitis
irritation
Irritant-Skin:
Data for related material suggests this may cause skin irritation
Reproductive and developmental:
None known
Skin contact:
The possibility of allergic sensitization should be considered
Chronic toxicity/Carcinogens:
None
Human Data:
Inhalation may cause respiratory irritation
|
Section
12: Environmental Information
Eco toxicity:
Destroys bacteria, viruses, spores and algae
Degradability and Persistence:
Fully Biodegradable
Bio-accumulation:
None
Mobility:
None
|
Section
13: Disposal Procedures
There are no special disposal procedures.
|
Section
14: Transport procedures
Not classified as hazardous for transport.
|
Section
15: Regulatory Information
Not listed
|
|
Section
16: Other Information
The information in this document meets the European requirements
for safety and health measurements. (91/155/EWG)
The
information contained in this document is based on data considered
to be accurate at the time of publication and is given free of
charge. It is representative of typical product but batches may
exhibit minor variations.
NO
warranty is expressed or implied concerning the accuracy
of this data.
In
case of doubt or for clarification Envirolyte should be consulted
to determine Safety and Suitability for the process and conditions
of use.
This
information is intended for use in the EC-countries only as different
limits may be set in other countries. Please check your Local
and National Authorities or Supplier. (91/155/EWG)
©
2005, Envirolyte Industries International Ltd. Tallinn, Estonia
Envirolyte
AQUASOLUTIONS India P.Ltd. Salem-India.
|
Material
Safety Data Sheet 3 |
Envirolyte
K-Catholyte (91/155/EWG) |
|
|
Section
1: Product and Company Identification
Scientific Name: Catholyte
Trade Name: Aquasol - A
Manufacturer/Supplier:
Envirolyte Industries International Ltd.
Narva str.1-330, 10111 Tallinn, Estonia
Indian Partner: Envirolyte AQUASOLUTIONS India
P.Ltd
|
Section
2: Composition and information on the ingredients
Catholyte contains hydroxyls and hydroxyl radicals such as NaOH,
H2O2-,HO-.The solution contains no compounds as per the regulations
for toxic compounds (67/548/EWG).
|
Section
3: Hazards identification
The solution is classified as non dangerous accordingly to 88/279/EWG.
Main Hazards:
Catholyte in the strongest form may cause slight irritation of
throat.
Health effects - Eyes:
Catholyte in the strongest form may cause slight irritation to
eyes.
Health effects - Skin:
Catholyte in the strongest form may cause irritation to sensitive
skin or open wounds.
Health effects - Ingestion:
Swallowing of the solution in its strongest form may cause slight
irritation to the throat and digestive tract.
Health effects - Inhalation:
During generation of the solution particularly its strong form
unless there is adequate ventilation there may be a build up of
fumes which may cause dizziness and nausea.
|
Section
4: First aid Measures
Eye contact:
Where irritation occurs flush with cool fresh water
Skin Contact:
Where irritation occurs wash the skin wash with soap and warm
water
Ingestion:
Drink cool fresh water to flush through and dilute
Inhalation:
Move to fresh air. If dizziness and nausea persist seek medical
attention.
|
Section
5: Fire Fighting Measures
There are no special requirements for these solutions they are
not flammable.
|
Section
6: Accidental Release Measures
Personal precautions:
None
Environmental precautions:
The solution is biodegradable and has a limited activation period
so there are no potential risks to the environment
Spillage:
Wipe up with disposable towels, there are no special disposal instructions.
|
Section
7: Handling and Storage
Handling:
In the area where the solution is being produced there must be
good ventilation. Preferably local exhaust ventilation. For those
with very sensitive skin it may be advisable to wear gloves.
Storage:
Store in a cool dry ventilated area in sealed plastic containers
and ensure the solution is correctly labeled. Shelf life up to
12 months.
|
Section
8: Personal Protection and Exposure Control
Engineering control procedures:
Where Catholyte is being generated on site some engineering solutions
should be implemented to prevent the build up of fumes particularly
if production facility has inadequate ventilation. Mechanical
fume extraction may be necessary in this situation.
Documented process, safety control and personnel protection where
necessary, gloves, mask etc.
Respiratory Protection:
Where there is a high risk to fumes build up due to inadequate
ventilation in a processing area a respirator should be worn.
Hand protection:
Where service personnel have sensitive skin the strongest solutions
may cause irritation and therefore protective gloves should be
worn.
Eye and facial protection:
There are no requirements.
Body protection:
Normal industrial work wears to avoid exposed skin when handling
neat strong solution.
|
Section
9: Chemical and Physical Properties
Physical state: Liquid
Color and Appearance: Clear, transparent liquid
(like water)
Odour: Slight chlorine smell varying with the
strength of the solution
Solubility in water: Completely soluble
PH-values: 10-13
Melting-point: 0oC.
Boiling-point: 100oC.
Fire-focus: N/A
Flammability: None
Explosive: N/A
Density: app. 1,000 kg.m3
Steam-pressure: app. 2,330 Pa
|
Section
10: Stability and Reactivity
Stability:
Stable under all normal storage conditions.
Materials to avoid:
The solution does not react with other materials.
Hazardous decomposition products:
None
|
Section
10: Stability and Reactivity
Stability:
Stable under all normal storage conditions.
Materials to avoid:
The solution does not react with other materials.
Hazardous decomposition products:
None
© 2005, Envirolyte Industries International
Ltd. Tallinn, Estonia
Envirolyte
AQUASOLUTIONS India P.Ltd. Salem-India
|
|
|
|
|